Multiplex Assay Kit for Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay)
ENHO; UNQ470; Energy Homeostasis Associated Protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMN251Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 494
US$ 513
US$ 542
US$ 580
US$ 618
US$ 675
US$ 760
Result
For more details, please contact local distributors! US$ 950 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 99-105 | 102 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 78-95 | 82 |
sodium citrate plasma(n=5) | 79-103 | 81 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-101% | 89-103% | 97-104% | 79-102% |
EDTA plasma(n=5) | 94-101% | 94-101% | 92-104% | 82-92% |
heparin plasma(n=5) | 89-103% | 98-105% | 95-102% | 95-103% |
sodium citrate plasma(n=5) | 80-93% | 78-90% | 82-103% | 86-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AD) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Pregnancy Hypertens. | Alteration of serum adropin level in preeclampsia. pubmed:28501281 |
Frontiers in Molecular Neuroscience | Adropin Is a Key Mediator of Hypoxia Induced Anti-Dipsogenic Effects via TRPV4-CamKK-AMPK Signaling in the Circumventricular Organs of Rats. pubmed:28473751 |
Preprints | Afamin and Adropin in Patients with Alcohol-Induced Liver Cirrhosis manuscript:201803.0258 |
Probiotics and Antimicrobial Proteins | Effects of Probiotic Yogurt on Serum Omentin-1, Adropin, and Nesfatin-1 Concentrations in Overweight and Obese Participants Under Low-Calorie Diet Pubmed: 30232744 |
Probiotics and Antimicrobial Proteins | Mitra Zarrati, Mahsa Raji Lahiji, Eisa Salehi, Bahareh Yazdani, Elham Razmpoosh, Raheleh Shokouhi Shoormasti & Farzad Shidfar Pubmed: 30232744 |
Pediatr Diabetes | Adropin and apelin‐12 efficiently predict metabolic syndrome in obese children Pubmed: 32749012 |
European Journal of Therapeutics | Effect of Peri-Implant Disease on Adropin Levels: A Cross-Sectional Pilot Study |
Horm Mol Biol Clin Investig | Effects of eight weeks exercise training on serum levels of adropin in male volleyball players 33794077 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPN251Mu01 | Recombinant Adropin (AD) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAN251Mu01 | Polyclonal Antibody to Adropin (AD) | WB; IHC; ICC; IP. |
SEN251Mu | ELISA Kit for Adropin (AD) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMN251Mu | Multiplex Assay Kit for Adropin (AD) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |