Multiplex Assay Kit for CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay)

OX2R; HCRTR2; CD200R; MOX2R; MOX2 Receptor; Cell surface glycoprotein CD200 receptor 1; CD200 cell surface glycoprotein receptor; Cell surface glycoprotein OX2 receptor 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-95 90
EDTA plasma(n=5) 90-97 93
heparin plasma(n=5) 91-101 97
sodium citrate plasma(n=5) 78-104 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 97-105% 79-102% 91-99%
EDTA plasma(n=5) 78-99% 80-89% 95-104% 96-103%
heparin plasma(n=5) 90-97% 94-103% 94-105% 93-101%
sodium citrate plasma(n=5) 79-89% 87-101% 81-94% 91-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CD200R1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Perfusion Inhibitory CD200R and proapoptotic CD95/CD95L molecules on innate immunity cells are modulated by cardiac surgery Pubmed:25404054
Medicine Pre-transplant CD200 and CD200R1 concentrations are associated with post-transplant events in kidney transplant recipients Pubmed: 31517819
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPN341Hu01 Recombinant CD200 Receptor 1 (CD200R1) Positive Control; Immunogen; SDS-PAGE; WB.
PAN341Hu01 Polyclonal Antibody to CD200 Receptor 1 (CD200R1) WB; IHC; ICC; IP.
MAN341Hu21 Monoclonal Antibody to CD200 Receptor 1 (CD200R1) WB; IHC; ICC; IP.
SEN341Hu ELISA Kit for CD200 Receptor 1 (CD200R1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMN341Hu Multiplex Assay Kit for CD200 Receptor 1 (CD200R1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.