Mini Samples ELISA Kit for Sex Hormone Binding Globulin (SHBG)

ABP; TEBG; SBP; Sex steroid-binding protein; Testis-specific androgen-binding protein; Testosterone-estradiol-binding globulin; Testosterone-estrogen-binding globulin

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Sex Hormone Binding Globulin (SHBG).
No significant cross-reactivity or interference between Mini Samples Sex Hormone Binding Globulin (SHBG) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Sex Hormone Binding Globulin (SHBG) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Sex Hormone Binding Globulin (SHBG) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-101 84
EDTA plasma(n=5) 92-99 95
heparin plasma(n=5) 85-104 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Sex Hormone Binding Globulin (SHBG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Sex Hormone Binding Globulin (SHBG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Sex Hormone Binding Globulin (SHBG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-97% 80-90% 78-103% 78-95%
EDTA plasma(n=5) 94-103% 88-95% 89-103% 85-96%
heparin plasma(n=5) 78-90% 81-102% 78-97% 80-88%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×60µL Assay Diluent A 1×6mL
Detection Reagent B 1×60µL Assay Diluent B 1×6mL
TMB Substrate 1×4.5mL Stop Solution 1×3mL
Wash Buffer (30 × concentrate) 1×10mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Nutrition and Cancer A Pilot Study Comparing the Effect of Flaxseed, Aromatase Inhibitor, and the Combination on Breast Tumor Biomarkers Tandfonline: Source
international journal of environmental research and public health Elevated Serum Bisphenol A Level in Patients with Dilated Cardiomyopathy PubMed: 25996886
Journal of Life Science Effects of Fermented Dandelion (Taraxacum coreanum) Extract on Male Climacteric Syndrome SMGHBM_2016_v26n9_1063
Scientific Reports Molecular characterization of insulin resistance and glycolytic metabolism in the rat uterus pubmed:27461373
33 Metformin Ameliorates Uterine Defects in a Rat Model of Polycystic Ovary Syndrome. pubmed:28336389
Toxicology and Applied Pharmacology Progressive effects of silver nanoparticles on hormonal regulation of reproduction in male rats pubmed:27746313
中国医药导报 益肾祛浊方对PCOS-IR大鼠Ghrelin、SHBG及VF的影响 yycyzx201733003
Journal of Endocrinology Uterine progesterone signaling is a target for metformin therapy in polycystic ovary syndrome Pubmed: 29535146
Biomed Pharmacother Comparative study on beneficial effects of vitamins B and D in attenuating doxorubicin induced cardiotoxicity in rats: Emphasis on calcium homeostasis 34029952
Food Science and Biotechnology Improvement of testosterone deficiency by fermented Momordica charantia extracts in aging male rats 33868755
Nutrients Yogurt Enriched with Inulin Ameliorated Reproductive Functions and Regulated Gut Microbiota in Dehydroepiandrosterone-Induced Polycystic Ovary Syndrome Mice Pubmed:35057459
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA396Mu01 Recombinant Sex Hormone Binding Globulin (SHBG) Positive Control; Immunogen; SDS-PAGE; WB.
RPA396Mu02 Recombinant Sex Hormone Binding Globulin (SHBG) Positive Control; Immunogen; SDS-PAGE; WB.
PAA396Mu02 Polyclonal Antibody to Sex Hormone Binding Globulin (SHBG) WB; IHC; ICC; IP.
PAA396Mu01 Polyclonal Antibody to Sex Hormone Binding Globulin (SHBG) WB; IHC; ICC; IP.
LAA396Mu71 Biotin-Linked Polyclonal Antibody to Sex Hormone Binding Globulin (SHBG) WB; IHC; ICC.
MAA396Mu21 Monoclonal Antibody to Sex Hormone Binding Globulin (SHBG) WB; IHC; ICC; IP.
SEA396Mu ELISA Kit for Sex Hormone Binding Globulin (SHBG) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA396Mu Mini Samples ELISA Kit for Sex Hormone Binding Globulin (SHBG) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA396Mu Multiplex Assay Kit for Sex Hormone Binding Globulin (SHBG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.