CLIA Kit for Epstein Barr Virus Induced Protein 3 (EBI3)

IL27B; IL27-B; Interleukin 27B; Epstein-Barr virus-induced gene 3 protein; EBV-induced gene 3 protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Epstein Barr Virus Induced Protein 3 (EBI3).
No significant cross-reactivity or interference between Epstein Barr Virus Induced Protein 3 (EBI3) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Epstein Barr Virus Induced Protein 3 (EBI3) and the recovery rates were calculated by comparing the measured value to the expected amount of Epstein Barr Virus Induced Protein 3 (EBI3) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-97 88
EDTA plasma(n=5) 79-102 90
heparin plasma(n=5) 81-92 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epstein Barr Virus Induced Protein 3 (EBI3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epstein Barr Virus Induced Protein 3 (EBI3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epstein Barr Virus Induced Protein 3 (EBI3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 89-98% 78-105% 83-97%
EDTA plasma(n=5) 87-104% 80-95% 96-103% 89-97%
heparin plasma(n=5) 86-93% 99-105% 93-101% 82-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
The Journal of Immunology Coordination between TLR9 Signaling in Macrophages and CD3 Signaling in T Cells Induces Robust Expression of IL-30 Jimmunol: 3709
PLoS One Lack of evidence for expression and function of IL-39 in human immune cells 33259477
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPD206Mu01 Recombinant Epstein Barr Virus Induced Protein 3 (EBI3) Positive Control; Immunogen; SDS-PAGE; WB.
RPD206Mu02 Recombinant Epstein Barr Virus Induced Protein 3 (EBI3) Positive Control; Immunogen; SDS-PAGE; WB.
PAD206Mu01 Polyclonal Antibody to Epstein Barr Virus Induced Protein 3 (EBI3) WB; IHC; ICC; IP.
PAD206Mu02 Polyclonal Antibody to Epstein Barr Virus Induced Protein 3 (EBI3) WB; IHC; ICC; IP.
SED206Mu ELISA Kit for Epstein Barr Virus Induced Protein 3 (EBI3) Enzyme-linked immunosorbent assay for Antigen Detection.
SCD206Mu CLIA Kit for Epstein Barr Virus Induced Protein 3 (EBI3) Chemiluminescent immunoassay for Antigen Detection.
LMD206Mu Multiplex Assay Kit for Epstein Barr Virus Induced Protein 3 (EBI3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.