ELISA Kit for Annexin V (ANXA5)

ANX5; ENX2; PP4; PAP-I; CBP-I; Anchorin CII; Calphobindin I; Endonexin II; Lipocortin V; Placental anticoagulant protein 4; Thromboplastin inhibitor; Vascular anticoagulant-alpha

Specificity

This assay has high sensitivity and excellent specificity for detection of Annexin V (ANXA5).
No significant cross-reactivity or interference between Annexin V (ANXA5) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Annexin V (ANXA5) and the recovery rates were calculated by comparing the measured value to the expected amount of Annexin V (ANXA5) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 83-97 89
heparin plasma(n=5) 85-94 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Annexin V (ANXA5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Annexin V (ANXA5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Annexin V (ANXA5) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-98% 78-99% 83-102% 90-99%
EDTA plasma(n=5) 79-104% 82-103% 81-103% 88-102%
heparin plasma(n=5) 79-105% 97-105% 80-91% 80-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Molecular Biology Markers of apoptotic dysfunctions in schizophrenia Pubmed: 24466757
Neuroscience and Behavioral Physiology Involvement of Anomalous Apoptosis in Impairments to Synaptic Plasticity in Post-Traumatic Stress Disorder Springer: Source
Inflammation and Cell Signaling Collectins, C3 complement protein, annexin V and C-reactive protein in acute ischemic stroke: interrelation and implication to upregulated apoptosis and inflammation Smartscitech: Source
Lung Annexin A5 Protein as a Potential Biomarker for the Diagnosis of Asthma Pubmed: 30182154
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA259Hu02 Active Annexin V (ANXA5) Cell culture; Activity Assays.
APA259Hu03 Active Annexin V (ANXA5) Cell culture; Activity Assays.
RPA259Hu04 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu01 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
APA259Hu06 Active Annexin V (ANXA5) Cell culture; Activity Assays.
APA259Hu01 Active Annexin V (ANXA5) Cell culture; Activity Assays.
RPA259Hu05 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
EPA259Hu61 Eukaryotic Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
APA259Hu61 Active Annexin V (ANXA5) Cell culture; Activity Assays.
RPA259Hu06 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu03 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA259Hu02 Recombinant Annexin V (ANXA5) Positive Control; Immunogen; SDS-PAGE; WB.
PAA259Hu01 Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
LAA259Hu71 Biotin-Linked Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC.
LAA259Hu81 FITC-Linked Polyclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IF.
MAA259Hu24 Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
MAA259Hu21 Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
MAA259Hu22 Monoclonal Antibody to Annexin V (ANXA5) WB; IHC
MAA259Hu23 Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IP.
FAA259Hu04 Anti-Annexin V (ANXA5) Monoclonal Antibody FCM
FAA259Hu02 Anti-Annexin V (ANXA5) Monoclonal Antibody FCM
LAA259Hu82 FITC-Linked Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC; IF.
LAA259Hu72 Biotin-Linked Monoclonal Antibody to Annexin V (ANXA5) WB; IHC; ICC.
FAA259Hu82 FITC-Linked Anti-Annexin V (ANXA5) Monoclonal Antibody FCM
SEA259Hu ELISA Kit for Annexin V (ANXA5) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA259Hu Multiplex Assay Kit for Annexin V (ANXA5) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.