ELISA Kit for Carbonic Anhydrase II (CA2)

CA-II; CAII; Car2; CAC; Carbonate dehydratase II; Carbonic anhydrase C

Specificity

This assay has high sensitivity and excellent specificity for detection of Carbonic Anhydrase II (CA2).
No significant cross-reactivity or interference between Carbonic Anhydrase II (CA2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Carbonic Anhydrase II (CA2) and the recovery rates were calculated by comparing the measured value to the expected amount of Carbonic Anhydrase II (CA2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-103 96
EDTA plasma(n=5) 83-95 87
heparin plasma(n=5) 94-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carbonic Anhydrase II (CA2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carbonic Anhydrase II (CA2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Carbonic Anhydrase II (CA2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-105% 86-94% 78-104% 99-105%
EDTA plasma(n=5) 80-91% 83-94% 88-104% 98-105%
heparin plasma(n=5) 95-104% 92-105% 93-101% 78-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Proteomics Clin Appl.  Identification of potential breast cancer markers in nipple discharge by protein profile analysis using two-dimensional nano-liquid chromatography/nanoelectrospray ionization-mass spectrometry. Pubmed:26970563
PROTEOMICS - Clinical Applications Comparative mass spectrometric and immunoassay-based proteome analysis in serum ofDuchenne muscular dystrophy patients. pubmed:26680509
Cell & Molecular Biology Identification of potential breast cancer markers in nipple discharge by protein profile analysis using two‐dimensional nano‐liquid chromatography/nanoelectrospray … doi:10.1002
Catalog No. Related products for research use of Rhesus monkey (Simian) Organism species Applications (RESEARCH USE ONLY!)
NPA782Si01 Native Carbonic Anhydrase II (CA2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA782Si01 Recombinant Carbonic Anhydrase II (CA2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA782Si02 Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
PAA782Si01 Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
LAA782Si71 Biotin-Linked Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC.
LAA782Si91 HRP-Linked Polyclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC.
MAA782Si22 Monoclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
MAA782Si21 Monoclonal Antibody to Carbonic Anhydrase II (CA2) WB; IHC; ICC; IP.
SEA782Si ELISA Kit for Carbonic Anhydrase II (CA2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA782Si Multiplex Assay Kit for Carbonic Anhydrase II (CA2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA782Si01 ELISA Kit DIY Materials for Carbonic Anhydrase II (CA2) Main materials for "Do It (ELISA Kit) Yourself".