ELISA Kit for Epithelial Cell Adhesion Molecule (EPCAM)

CD326; TACSTD1; EGP; KSA; M4S1; MIC18; TROP1; HEGP2; ESA; Epithelial glycoprotein; Adenocarcinoma-associated antigen; Tumor Associated Calcium Signal Transducer 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Epithelial Cell Adhesion Molecule (EPCAM).
No significant cross-reactivity or interference between Epithelial Cell Adhesion Molecule (EPCAM) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Epithelial Cell Adhesion Molecule (EPCAM) and the recovery rates were calculated by comparing the measured value to the expected amount of Epithelial Cell Adhesion Molecule (EPCAM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-104 101
EDTA plasma(n=5) 79-104 91
heparin plasma(n=5) 79-90 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epithelial Cell Adhesion Molecule (EPCAM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epithelial Cell Adhesion Molecule (EPCAM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epithelial Cell Adhesion Molecule (EPCAM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 84-101% 96-104% 85-102%
EDTA plasma(n=5) 92-101% 94-105% 83-90% 78-102%
heparin plasma(n=5) 93-102% 83-99% 79-97% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Sensors and Actuators B: Chemical Epithelial cancer biomarker EpCAM determination in peripheral blood samples using a microfluidic immunosensor based in silver nanoparticles as platform Science: Article
Microchemical Journal Nanostructured platform integrated into a microfluidic immunosensor coupled to laser-induced fluorescence for the epithelial cancer biomarker determination science:S0026265X16300091
Arab Journal of Gastroenterology Role of several cytokines and adhesion molecules in the diagnosis and prediction of survival ofhepatocellular carcinoma. pubmed:27916547
Clinica Chimica Acta Integrated bio-affinity nano-platform into a microfluidic immunosensor based on monoclonal bispecific trifunctional antibodies for the electrochemical determination of … pubmed:27836687
Clinica Chimica Acta Integrated bio-affinity nano-platform into a microfluidic immunosensor based on monoclonal bispecific trifunctional antibodies for the electrochemical determination of epithelial cancer biomarker 10.1016/j.cca.2016.11.012
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB283Hu01 Recombinant Epithelial Cell Adhesion Molecule (EPCAM) Positive Control; Immunogen; SDS-PAGE; WB.
PAB283Hu01 Polyclonal Antibody to Epithelial Cell Adhesion Molecule (EPCAM) WB; IHC; ICC; IP.
MAB283Hu21 Monoclonal Antibody to Epithelial Cell Adhesion Molecule (EPCAM) WB; IHC; ICC; IP.
MAB283Hu22 Monoclonal Antibody to Epithelial Cell Adhesion Molecule (EPCAM) WB; IHC; ICC; IP.
SEB283Hu ELISA Kit for Epithelial Cell Adhesion Molecule (EPCAM) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB283Hu Multiplex Assay Kit for Epithelial Cell Adhesion Molecule (EPCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.