ELISA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

AIF1; IRT1; Daintain; Protein G1; Allograft Inflammatory Factor 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Ionized Calcium-binding Adapter Molecule 1 (IBA1).
No significant cross-reactivity or interference between Ionized Calcium-binding Adapter Molecule 1 (IBA1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) and the recovery rates were calculated by comparing the measured value to the expected amount of Ionized Calcium-binding Adapter Molecule 1 (IBA1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-98 91
EDTA plasma(n=5) 84-96 89
heparin plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ionized Calcium-binding Adapter Molecule 1 (IBA1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 87-97% 83-90% 78-104%
EDTA plasma(n=5) 98-105% 91-101% 79-94% 93-103%
heparin plasma(n=5) 94-103% 80-89% 98-105% 80-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosci Trends. Allograft inflammatory factor-1 in the pathogenesis of bleomycin-induced acute lung injury Pubmed:26911661
Cardiovasc Pathol A novel role for the Krüppel-like factor 14 on macrophage inflammatory response and atherosclerosis development pubmed:27923151
IOS Press Content Library An Intranasal Formulation of Erythropoietin (Neuro-EPO) Prevents Memory Deficits and Amyloid Toxicity in the APPSwe Transgenic Mouse Model of Alzheimer's … articles:journal-of-alzheimers-disease
博士论文 INSTITUTO DE CIENCIAS BÁSICAS Y PRECLÍNICAS “VICTORIA DE GIRÓN” DEPARTAMENTO DE HISTOLOGÍA
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPC288Ra01 Recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC288Ra01 Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
LAC288Ra71 Biotin-Linked Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC.
MAC288Ra22 Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
MAC288Ra21 Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB
MAC288Ra23 Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
MAC288Ra24 Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
MAC288Ra25 Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
LAC288Ra72 Biotin-Linked Monoclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC.
SEC288Ra ELISA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC288Ra CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Chemiluminescent immunoassay for Antigen Detection.
LMC288Ra Multiplex Assay Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSC288Ra01 Antibody Pair for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ELISA,CLIA,ELISPOT,Luminex
KSC288Ra01 ELISA Kit DIY Materials for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Main materials for "Do It(ELISA Kit) Yourself"