ELISA Kit for Nuclear Mitotic Apparatus Protein 1 (NUMA1)

NMP22; NUMA; Nuclear matrix protein-22; SP-H antigen

Specificity

This assay has high sensitivity and excellent specificity for detection of Nuclear Mitotic Apparatus Protein 1 (NUMA1).
No significant cross-reactivity or interference between Nuclear Mitotic Apparatus Protein 1 (NUMA1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Nuclear Mitotic Apparatus Protein 1 (NUMA1) and the recovery rates were calculated by comparing the measured value to the expected amount of Nuclear Mitotic Apparatus Protein 1 (NUMA1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 97
EDTA plasma(n=5) 80-90 84
heparin plasma(n=5) 92-99 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nuclear Mitotic Apparatus Protein 1 (NUMA1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nuclear Mitotic Apparatus Protein 1 (NUMA1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nuclear Mitotic Apparatus Protein 1 (NUMA1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-101% 80-95% 89-105% 97-105%
EDTA plasma(n=5) 82-101% 78-96% 84-101% 91-101%
heparin plasma(n=5) 89-103% 92-104% 99-105% 79-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Oncotarget Identification and validation of AIB1 and EIF5A2 for noninvasive detection of bladder cancer inurine samples. pubmed:27203388
Journal of Micromechanics and Microengineering A simple fabricated microfluidic chip for urine sample-based bladder cancer detection
Journal of Electroanalytical Chemistry A highly sensitive label-free electrochemical immunosensor based on AuNPs-PtNPs-MOFs for nuclear matrix protein 22 analysis in urine sample
Electrophoresis Bladder cancer hunting: a microfluidic paper‐based analytical device Pubmed: 32530061
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC332Hu01 Recombinant Nuclear Mitotic Apparatus Protein 1 (NUMA1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC332Hu02 Recombinant Nuclear Mitotic Apparatus Protein 1 (NUMA1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC332Hu02 Polyclonal Antibody to Nuclear Mitotic Apparatus Protein 1 (NUMA1) WB; IHC; ICC; IP.
PAC332Hu01 Polyclonal Antibody to Nuclear Mitotic Apparatus Protein 1 (NUMA1) WB; IHC; ICC; IP.
MAC332Hu21 Monoclonal Antibody to Nuclear Mitotic Apparatus Protein 1 (NUMA1) WB; IHC; ICC; IP.
MAC332Hu22 Monoclonal Antibody to Nuclear Mitotic Apparatus Protein 1 (NUMA1) WB; IHC; ICC; IP.
SEC332Hu ELISA Kit for Nuclear Mitotic Apparatus Protein 1 (NUMA1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC332Hu Multiplex Assay Kit for Nuclear Mitotic Apparatus Protein 1 (NUMA1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSC332Hu01 Antibody Pair for Nuclear Mitotic Apparatus Protein 1 (NUMA1) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.