Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7)
CMD1S; CMH1; MPD1; MYHCB; Myopathy,Distal 1; Myosin heavy chain slow isoform; Myosin heavy chain, cardiac muscle beta isoform
- Product No.SED418Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.156-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.060ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 490
For more details, please contact local distributors! US$ 700 US$ 3150 US$ 5950 US$ 49000
Specificity
This assay has high sensitivity and excellent specificity for detection of Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7).
No significant cross-reactivity or interference between Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) and the recovery rates were calculated by comparing the measured value to the expected amount of Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-96 | 85 |
EDTA plasma(n=5) | 95-103 | 99 |
heparin plasma(n=5) | 79-104 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myosin Heavy Chain 7, Cardiac Muscle, Beta (MYH7) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-97% | 85-104% | 99-105% | 89-104% |
EDTA plasma(n=5) | 89-96% | 91-105% | 91-99% | 78-102% |
heparin plasma(n=5) | 94-103% | 83-101% | 98-105% | 89-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Life Sciences | Cardioprotective effect of cerium oxide nanoparticles in monocrotaline rat model of pulmonary hypertension: A possible implication of endothelin-1 Pubmed:29588134 |
Archives of Medical Research | Irisin vs. Treadmill Exercise in Post Myocardial Infarction Cardiac Rehabilitation in Rats |
Passive repetitive stretching increases skeletal muscle mass and myo 17143883 | |
Sci Rep | Passive repetitive stretching is associated with greater muscle mass and cross-sectional area in the sarcopenic muscle 34315961 |