Multiplex Assay Kit for Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay)

UI; UROC; Urocortin 1; UCN1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-94 90
EDTA plasma(n=5) 80-89 80
heparin plasma(n=5) 80-99 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-99% 92-99% 80-89% 78-98%
EDTA plasma(n=5) 82-98% 96-105% 94-102% 95-103%
heparin plasma(n=5) 93-102% 93-101% 98-105% 82-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:UCN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Human Reproduction P-205 Basement membrane integrity is altered in the late secretary phase in women with endometriosis: implications for the pathogenesis of endometriosis OxfordJournals: source
PLOS ONE Vasoprotective effects of urocortin 1 against atherosclerosis in vitro and in vivo Pubmed:25462164
Taiwan J Obstet Gynecol Novel markers in the diagnostics of endometriomas: Urocortin, ghrelin, and leptin or leukocytes, fibrinogen, and CA-125? PubMed: 25951715
Biomedical Journal of Scientific & Technical Research Anti-Inflammatory and Pro-Inflammatory Neuropeptides in Dilative Cardiomyopathy are there Relations to Psychophysical Stress?
Neurobiol Stress Erasing m6A-dependent transcription signature of stress-sensitive genes triggers antidepressant actions 34527794
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA231Hu02 Recombinant Urocortin (UCN) Positive Control; Immunogen; SDS-PAGE; WB.
RPA231Hu01 Recombinant Urocortin (UCN) Positive Control; Immunogen; SDS-PAGE; WB.
CPA231Hu21 OVA Conjugated Urocortin (UCN) Immunogen; SDS-PAGE; WB.
PAA231Hu08 Polyclonal Antibody to Urocortin (UCN) WB; IHC; ICC; IP.
PAA231Hu01 Polyclonal Antibody to Urocortin (UCN) WB; IHC; ICC; IP.
LAA231Hu71 Biotin-Linked Polyclonal Antibody to Urocortin (UCN) WB; IHC; ICC.
MAA231Hu22 Monoclonal Antibody to Urocortin (UCN) WB; IHC; ICC; IP.
SEA231Hu ELISA Kit for Urocortin (UCN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA231Hu Multiplex Assay Kit for Urocortin (UCN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.