Multiplex Assay Kit for Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay)
SLC6A4; SLC6-A4; HTT; 5-HTT; 5HTT; OCD1; hSERT; Solute Carrier Family 6,Member 4; Neurotransmitter Transporter,Serotonin; Sodium-dependent serotonin transporter
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC890Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 437
US$ 454
US$ 479
US$ 512
US$ 546
US$ 596
US$ 672
Result
For more details, please contact local distributors! US$ 840 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-105 | 102 |
EDTA plasma(n=5) | 85-96 | 90 |
heparin plasma(n=5) | 86-94 | 90 |
sodium citrate plasma(n=5) | 94-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-98% | 78-89% | 80-104% | 98-105% |
EDTA plasma(n=5) | 92-99% | 98-105% | 83-95% | 88-99% |
heparin plasma(n=5) | 91-101% | 82-97% | 85-104% | 80-96% |
sodium citrate plasma(n=5) | 91-99% | 93-101% | 78-98% | 78-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:SERT) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journal of Prosthodontic Research | Comparison of platelet serotonin transporter activity in subjects with severe sleep bruxism and control Pubmed:25127373 |
Frontiers in Behavioral Neuroscience? | Experimental heart failure causes depression-like behavior together with differential regulation of inflammatory and structural genes in the brain Pubmed:25400562 |
Sleep Breath | Sleep bruxism frequency and platelet serotonin transporter activities in young adult subjects PubMed: 26527205 |
PLoS One. | Non-Serotonergic Neurotoxicity by MDMA (Ecstasy) in Neurons Derived fromMouse P19 Embryonal Carcinoma Cells. pubmed:27861613 |
Herz-Hirn Interaktion im Mausmodell: Herzinsuffizienz nach Myokardinfarkt führt zu depressivem Verhalten bei Mäusen frontdoor:index | |
Effects of Junk Foods on Brain Neurotransmitters (Dopamine and Serotonin) and some Biochemical Parameters in Albino Rats article_1486_c0fa9f8afe5f70b407e7195bcfd55c70 | |
Toxicology Reports | Neuro-and nephroprotective effect of grape seed proanthocyanidin extract against carboplatin and thalidomide through modulation of inflammation, tumor … Pubmed:29854627 |
Journal of Taibah University for Science | Neurotoxicity and inflammation induced by individual and combined exposure to iron oxide nanoparticles and silver nanoparticles |
NEUROGASTROENTEROLOGY AND MOTILITY | Effects of regulating gut microbiota on the serotonin metabolism in the chronic unpredictable mild stress rat model Pubmed: 31323174 |
Thrombosis Research | VAMP8 and serotonin transporter levels are associated with venous thrombosis risk in a Spanish female population. Results from the RETROVE Project Pubmed: 31382081 |
Scientia Psychiatrica | Neuronal Cell Death Induces Depressive Disorder in Rats Depression-Like Behaviors Caused by Chronic Stress |
Journal of Immunology | Administration of a Probiotic Mixture Ameliorates Cisplatin-Induced Mucositis and Pica by Regulating 5-HT in Rats 34568500 |
Biol Pharm Bull | Targeting the oxytocin system to ameliorate early life depressive-like behaviors in maternally-separated rats 34349049 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPC890Hu01 | Recombinant Serotonin Transporter (SERT) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC890Hu01 | Polyclonal Antibody to Serotonin Transporter (SERT) | WB; IHC; ICC; IP. |
MAC890Hu21 | Monoclonal Antibody to Serotonin Transporter (SERT) | WB; IHC; ICC; IP. |
MAC890Hu22 | Monoclonal Antibody to Serotonin Transporter (SERT) | WB; IHC; ICC; IP. |
SEC890Hu | ELISA Kit for Serotonin Transporter (SERT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC890Hu | Multiplex Assay Kit for Serotonin Transporter (SERT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSC890Hu01 | ELISA Kit DIY Materials for Serotonin Transporter (SERT) | Main materials for "Do It(ELISA Kit) Yourself" |